BCS-460 Brew Session

>> Monday, June 29, 2009

Today I’m documenting a full BCS-460 brew session. I’m brewing a Toasted Coconut Porter based on the recipe by Fujiura, the 1998 Homebrewer of the Year. I found the recipe on the Internet so hopefully it’s true to the original.

My disclaimer, I don't work for Embedded Control Concepts nor am I associated with them in any way. But I do think this is a great product and I'm excited about it so I thought it might be helpful to others by documenting a brew session from start to boil.


Grain Bill
9 lbs Maris Otter Pale Malt (2 Row)
1 lbs 9.6 oz Hugh Baird Chocolate Malt
9.6 oz Briess Crystal Malt - 80L
1.25 oz Northern Brewer [8.50 %] (60 min) Hops 35.9 IBU
0.60 oz Goldings, East Kent [5.00 %] (10 min) Hops 3.7 IBU
1 Pkgs London Ale III (Wyeast Labs #1318) Yeast-Ale

Mash Profile
Mash at 153 for 90 minutes

Recipe Notes
14.2 ounces toasted coconut. Use dried unsweetened coconut and toast on cookie sheet 15 min at 350 in oven or carefully toast in a fry pan. Rack beer onto coconut in secondary for 7 days.


My BCS-460-based HERMS
My HERMS consists of a Hot Liquor Tun, a Heat Exchanger, a Mash Tun, a March brew pump, and a BCS-460 equipped with two temperature probes. The BCS-460 is mounted remotely in the utility room in my basement. I ran some CAT 6 cable to the back patio and this is used to control the heating elements and also for connecting the temp probes. I also have two separate 20 amp GFCI circuits on the back patio. The HLT is connected to one of these circuits and the HEX is connected to the other. The heating elements are 1500 watt, 120 volt elements drawing approx 12.5 amps each. The solid state relays for controlling the heating elements and pump are mounted in the small electrical box mounted on the brew stand. The benefit of the BCS-460 controller is that it allows you to precisely control things like mash temp which helps the home brewer have more easily repeatable results. Check out my other blog posts for more info and pics of my HERMS. Check out http://www.embeddedcontrolconcepts.com/ for more info on the BCS-460.

















Brewing Process
I programmed my BCS-460 for a single infusion mash. At the very bottom of this post you'll find the text from the configuration file for my system. The process consists of 7 states.


System Startup
The first state is System Startup where the Heat Exchanger (HEX) is preheated and the strike water is heated in the Hot Liquor Tun (HLT). I’m using 1.5 quarts of strike water per pound of grain for this recipe and my brewing software calculated an initial strikewater temp of 165.3 was needed. Here you can see a screen shot of the BCS-460 at work during startup. One note, my laptop doesn’t have the greatest graphics card so I zoomed out in the browser to be able to capture as much of the screen as possible. As a result it cuts part of the bottom off of temp probe graphics. It took 44 minutes to heat 16.8 quarts to 165.3. Also, the HEX has two different positions for the HEX temp probe. During Startup, the Temp probe is inserted into the top of the HEX and is measuring the temp of the water in the HEX. At Dough-in, the HEX temp probe is switched to position 2 where it’s measuring the temp of the mash exiting the HEX. This state is exited by clicking on the Web Input 0 button.




Start Mash
The next State is Start Mash. This state is essentially a pause that allows for stirring the grain and strikewater into the mash tun. The heating elements in the HEX and HLT are turned off at this time. This state is exited by clicking on the Web Input 0 button.




Dough-In
The next state is Dough-in. This is simply a count-down timer for 6 minutes. When the timer reaches 0:00, the Dough-In state is exited and the Mash state begins. 6 minutes may seem a little short for dough in, but keep in mind before I kicked off this state I refilled the HLT, checked hoses, and swapped the HEX temp probe from position 1 to position 2. So the total dough-in time is probably closer to 15 minutes. Also, since the HEX temp has been switched to position 2 but the mash isn’t being circulated yet, the temp reading on the HEX isn’t accurate at this time.




Mash
During the Mash state, the mash is being recirculated through the HEX and the water in the HLT is heated for the sparge. The heating element in the HEX is cycled on as needed in order to maintain the mash temp. You can see in the pic below the temp of the mash exiting the HEX is at 153.1, the HLT is heating the sparge water, and the pump is active. Also, Timer 0 is used to countdown the 90 minute mash. When the timer reaches 0:00, the Mash state is exited to the Mash Out state.










Mash Out
During this state the temp of the mash is raised to 168. Once the mash out temp is reached, the state is exited to Start Sparge. The HLT is maintained at 165. As you can see it took a little under 7 minutes to raise the mash temp to 168.







Start Sparge
Similar to Start Mash, this state is essentially a pause that allows for swapping hoses and such. This is exited by clicking on the Web Input 0 button. Essentially everything is turned off.

Sparge
During this state the heating element in the HLT is turned off. The HEX is powered on when the sparge water drops below the setpoint of 170. This state is exited by clicking on the Web Input 0 button. At some point I’d like to add some float switches to control the end of this state.




The rest of the brewing process (boil and chilling) is manual, so that's about it as far as the BCS-460 controlled portion. Hopefully that was helpful to those that are considering purchasing a BCS-460 or have purchased one and were a little confused as to where to start.

Single Infusion Mash Configuration



Read more...

BCS-460 First Trial

>> Monday, April 20, 2009

My BCS-460 HERMS is fully functional. I brewed my first batch on it on 4/25 and everything went fairly well. The only problem I had was for mash out I'm raising the temp from the mash temperature (in this case 158 F) to 168 F. I was able to raise the temp over a period of about 10 minutes. Then I swapped hoses and routed the sparge water through the HEX. The problem was the temp of the HEX was actually higher than the 168 from heating the mash, so my sparge water was getting heated to approx 172. No problem, I just removed the copper coil from the HEX and the temp dropped to 168. I think next time I'll either reduce the temp of the HEX during mashout or I'll reduce the temp of the sparge water in the HLT.

Anyway, here are some pics I took during the inaugural brew session and also a few I took during construction. The quality isn't all that great in some. For the brew session I brewed indoors due to bad weather so the lighting isn't all that great.






Read more...

Programming the BCS-460

>> Sunday, April 05, 2009

For those not familiar with the BCS-460, it's a web-based process controller available from Embedded Control Concepts. The BCS-460 allows brewers to automate certain processes and closely control things like mash temperature. The goal is to brew more consistently with more easily repeatable results. So if I brew "Recipe A" on three separate occasions, the end product should be very similar each time.

I've setup the initial programming on my BCS-460. I'm sure I'll tweak the programming slightly after a few trials, but here is the logic as it exists right now. I've named Process 0 Single Inf Mash and it consists of the following states:

  • System start
  • Start Mash
  • Dough-in
  • Mash
  • Mash Out
  • Start Sparge
  • Sparge

System Start

This state controls the heating elements in the Hot Liquor Tank (HLT) and Heat Exchanger (HEX). The water in the HLT will be heated for the strike water. The BCS-460 will heat the water to the desired temperature. This process is exited by clicking on one of the user input buttons.


Start Mash

During this state, only the HEX is on. This allows for transferring the strike water from the HLT to the mash tun, hose swaps, etc. This process is also exited by clicking on an input button. After the strike water is transferred to the mash tun, I refill the HLT with water to be used for the sparge.

Dough-In

This state powers on the HEX and HLT. The exit condition is based on a timer initialized at 12 minutes. When the timer gets to 0:00, the state is exited to the Mash.

Mash

During this state, the HLT, HEX, and pump are powered on. The mash liquid is circulated through the HEX in order to maintain temperature. The HLT's sparge water is heated to 170. This state is also controlled by a timer initialized to 60 minutes.

Mash Out

This state raises the mash temperature for mash out. The HLT, HEX, and pump are being controlled. Once the desired mash out temperature is reached, the state is exited.

Start Sparge

During this state the HLT and HEX are maintained at 170 degrees while the pump is turned off. This allows time for swapping hoses. This state is exited by clicking on a button.

Sparge

During this state the HLT is off, the HEX is on, and the pump is on and the sparge water is pumped into the mash tun. This state is exited by clicking on a button.



I still have a few plumbing fittings to buy as well as some electrical components. I hope to have these items pieced together within a couple weeks so that I can run the BCS-460 through some trials before my first brewing attempt.


Read more...

HERMS Design

>> Sunday, March 01, 2009

I'm in the process of building a HERMS system. The brains of the system is the BCS-460 Programmable Logic Controller from Embedded Control Concepts. It will be composed of the basic elements present in other HERMS systems:
  1. Hot Liquor Tank (HLT) - 5 gallon Rubbermaid cooler heated by a 1500 watt 120 volt water heater element
  2. Heat Exchanger (HX) - 2 gallon Rubbermaid Cooler heated by a 1500 watt 120 volt water heater element and consisting of 10 feet of 1/2" copper tubing
  3. Mash / Lauter Tun (MLT) - 10 gallon Rubbermaid cooler
  4. Pump - Brand a model to be determined
  5. Boil Kettle - 8 gallon
The controller will be used to turn the heating elements and pump on and off at various times throughout the brewing process.

Hot Liquor Tank >>


Read more...

HERMS Equipment - Hot Liquor Tank

The Hot Liquor Tank is based on a 5 gallon Rubbermaid cooler. The lid is drilled in the center and a temperature probe for the BCS-460 has been inserted. The HLT is heated by a 1500 watt 120 volt water heater element.

Heat Exchanger >>





Read more...

HERMS Equipment - Heat Exchanger

The Heat Exchanger is based on a 2 gallon Rubbermaid cooler. It holds approximately 1.5 gallons of water and is heated by a 1500 watt 120 volt water heater element. The heat exchange is accomplished with 10 feet of 1/2" copper tubing.

Mash Tun >>







Read more...

HERMS Equipment - Mash Tun

The Mash Tun is based on a 10 gallon Rubbermaid cooler. The lid is drilled and fitted with a grommet through which the return manifold is fitted. The return manifold is used for circulating the mash and for delivering the sparge water. It's contructed of 1/2" copper pipe and I've cut slots into the end of the T section in order to distribute the liquid without disturbing the grain bed.

1. System Startup >>


Read more...

1. System Startup

Controller turns on heating elements in Hot Liquor Tank and Heat Exchanger and heats water to preset temperatures. The water in the HLT will be transferred to the MLT and used for the mash in. Since the HEX is only 1.5 gallons and will not take very long to heat, it will probably be turned on after the strike water reached the target temp.
2. Mash >>

Read more...

2. Mash

The mash will be circulated by the pump. It will travel from MT to Pump to HX and back to MT. The HX will be used to maintain mash temperature for single infusion mashes and to increase temperature for step mashes and mash out. Sparge water will be heating in the HLT during the mashing process.

3. Sparge >>

Read more...

3. Sparge

During the sparge, hot water is pumped through the HX to the MT and the sweet runnings are collected from the MT in the BK. I may end up bypassing the HX, it just depends on whether I run into any problems with the HLT temps.

Read more...